SV100-4T-0110G أنفرتر 15حصان 380 ف

0ج.م
النوع : SV100-4T-0011G أنفرتر 15حصان 380 ف
حالة التوفر : 1
الكلمات الدليليلة :
Key technology data and function
Input
Rated voltage/frequency
3-phase, 380V440V AC. 50Hz/60Hz
Applicable voltage range
Voltage: 320V~460V, Voltage unbalancedness:<3%. Frequency tolerance: ±%5
Output
Rated voltage
380V
Frequency
0Hz300Hz.
Overload capacity
G Type: 150% rated current 1 minute, 180% rated current 10 seconds
Control Characteristics
Control method
Vector control without PG, V/F control
Modulation System
Space vector PWM modulation
Starting torque
0.5Hz 150rated torque(Vector control without PG)
Frequency accuracy
Digital setting: 0.01Hz. Analog setting: Max. frequency ×±0.2%
Frequency resolution
Digital setting: 0.01Hz. Analog setting: Max. frequency ×±0.05%
Torque boost
Manual torque boost: 0%~30.0%
V/F Pattern
4 patterns: one pattern is V/F curve setting by users, the other three are drop torque character curve(2.0 power, 1.7 power, 1.2 power)
Acceleration/Deceleration curve
Linear acceleration/deceleration. Four kinds of acceleration/deceleration time are optional
DC braking
Braking starting frequency:.00~60.00Hz Braking time:0.0~10.0s Braking current: 0.0~100.0%
Auto current limit
Auto limit the current during operation to prevent frequent overcurrent trip.
Customized function
Jogging
Jogging frequency range: 0.0Hz~50.00Hz. Jogging acceleration/deceleration time: 0.1~60.0s.
Multiple speed operation
Implement multiple speed operation by digital inputs
Operation function
Operation command
Keypad setting, Terminal setting, Communication setting.
Frequency command
Keypad setting, Analog input, Pulse input, Communication setting
Auxiliary frequency setting
Implement flexible auxiliary frequency trim and frequency synthesis
Pulse output
0~100KHz pulse output
Analog output
2 channels analog output(1/4~20mA or 0/2~10v)
Operation panel
LED Display
Display setting frequency, output frequency, output voltage, output current and so on, about 20 parameters
Parameters copy
Copy parameters by operation panel
Keys lock and function selection
Lock part of keys or all the keys . Define the function of part of keys
Protection functions
Protection functions
Dopen phase protection (Optional), overcurrent protection, overvoltage protection, undervoltage protection, overheat protection, overload protection and so on.
Environment
Operating site
Indoor, installed in the environment free from direct sunlight, dust, corrosive gas, combustible gas, oil mist, steam and drip.
Altitude
Derated above 1000m, the rated output current should be decreased by 10% for every rise of 1000m
Ambient temperature
0~40, when temperature is higher than 40, the power is derated.
Humidity
5%~95% RH, non-condensing.
Vibration
Less than 5.9m/S ²(0.6 g)
Storage temperature
minus 40C~70C
Structure
Protection class
IP20
Cooling method
 Air cooling, with fan control.
Installation
Wall-mounted
Efficiency
45KW or below: >93%; 55KW or above: >95%.
 

 